This is a genuine OEM 2-pole, 30-amp contactor (part number 1178074) with a 24V control coil for the ICP / Tempstar / Heil RGS120LRBA0AAA unit. The contactor is the electrically controlled switch that delivers line voltage to the compressor and condenser fan motor whenever the thermostat calls for cooling. When the 24V coil energizes, it pulls the contacts closed and powers the high-voltage loads. A failed contactor is one of the most common causes of a system that won't start, hums but won't engage, or runs continuously because the contacts have welded shut. Pitted, burned, or chattering contacts also cause hard starts and premature compressor wear.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24 VAC
Fitment OEM

Compatibility

Direct-fit replacement for the ICP RGS120LRBA0AAA and shared across many ICP, Tempstar, Heil, Comfortmaker, and Arcoaire platforms using a 2-pole 30A / 24V coil contactor. Always confirm your existing contactor's amperage and coil voltage against the unit's wiring diagram before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the outdoor disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the condensing unit service panel.
  3. Document — Photograph all wire positions before disconnecting anything.
  4. Remove — Label and detach line, load, and 24V coil leads; unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor, then reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contacts pull in on a cooling call and the compressor/fan energize.

Signs You Need a Replacement

  • System hums but the compressor and fan won't start.
  • Burned, pitted, or melted contacts visible on the old part.
  • Chattering or buzzing from the contactor.
  • Outdoor unit runs continuously because contacts are welded closed.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120LRBA0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120LRBA0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120LRBA0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online