Overview

This OEM 2-pole, 30-amp contactor (P/N 1178074) with a 24-volt control coil is the electrical switch that energizes the compressor and condenser fan in the ICP / Tempstar / Heil RGS120LRAA0AGAA. When the thermostat calls for cooling, 24V from the control board pulls the contactor in, closing both poles and sending line voltage to the outdoor unit. Contactors are a high-wear item: the contacts arc every cycle and eventually pit, burn, or weld shut, while ants and debris can jam the plunger. A failing contactor causes hard starts, chattering, a unit that won't shut off, or no outdoor operation at all. This direct replacement restores reliable switching.

Specifications

Spec Value
Part Number 1178074
Type Definite purpose contactor, 2-pole
Brand ICP / Tempstar / Heil
Rating 30 Amps
Coil Voltage 24V
Poles 2
Fit OEM direct replacement

Compatibility

Built for the ICP RGS120LRAA0AGAA and broadly compatible with ICP-family condensing units and furnaces sold as Tempstar, Heil, Comfortmaker, and Arcoaire that specify a 2-pole 30A definite-purpose contactor with a 24V coil. Match poles, amperage, and coil voltage to your original.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical/service panel to expose the contactor.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Unfasten the old contactor and transfer wires one at a time, or label each lead.
  5. Install — Mount the new contactor and reconnect line, load, and coil leads exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the unit runs.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Buzzing, chattering, or humming at the contactor
  • Compressor/fan won't start or won't shut off
  • Visible debris or melted housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120LRAA0AGAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120LRAA0AGAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120LRAA0AGAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.