This OEM 2-pole, 30 amp contactor with a 24V coil (OEM #1178074) is the main switching contactor for the ICP / Tempstar / Heil RGS120HFAA0AAA unit. The 24-volt control coil pulls in the contacts to deliver line power to the compressor and condenser fan motor on a cooling call, then drops them out when the call ends. Contactors are a high-wear part — the contacts arc on every cycle and eventually pit, burn, or weld, leading to a unit that won't start, won't shut off, or chatters. This direct-fit 30A / 2-pole replacement restores reliable, full-load switching.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fits Model RGS120HFAA0AAA
Fitment OEM direct replacement

Compatibility

Factory switching contactor for the ICP/Tempstar/Heil RGS120HFAA0AAA and RGS120-series units. The 2-pole / 30A contact rating and 24V coil match the factory compressor and condenser-fan load exactly.

Installation Guide

  1. Safety First — Disconnect power at the outdoor/indoor disconnect and verify zero voltage across all contactor terminals with a multimeter.
  2. Access — Remove the electrical-access service panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, unscrew the old contactor, and lift it out.
  5. Install — Mount the new contactor and reconnect each wire to its matching terminal per your photo.
  6. Test — Restore power and start a cooling call; confirm the contactor pulls in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • Compressor and fan won't start even though the coil is getting 24V.
  • Unit won't shut off because the contacts are welded closed.
  • Buzzing or chattering from the contactor on a call.
  • Visibly pitted, burned, or melted contacts.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120HFAA0AAA — 24V Coil OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120HFAA0AAA — 24V Coil OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120HFAA0AAA — 24V Coil OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.