Overview

This OEM 2-pole 30-amp contactor with a 24V coil (part number 1178074) is the factory switching relay for the ICP / Tempstar / Heil RGS120HEAB0AAA. When the thermostat calls, the control board sends 24V to the contactor coil, pulling in the contacts that close the high-voltage line to energize the load. The contactor is one of the hardest-working parts in the system — every cycle pulls the contacts together under load, and over time they pit, burn, and weld. A failed contactor either won't pull in (no operation) or sticks closed (load runs continuously and won't shut off). Replacing it with the correct 2-pole 30A / 24V unit restores reliable, clean switching.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fit OEM Direct Replacement

Compatibility

Built for the ICP RGS120HEAB0AAA and a broad range of Tempstar, Heil and Comfortmaker units using a 2-pole 30A definite-purpose contactor with a 24V coil. Match poles, amperage, and coil voltage to your old part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage at the contactor with a multimeter.
  2. Access — Remove the electrical compartment service panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew the old contactor from its base.
  5. Install — Mount the new contactor and land each wire on the matching terminal per your photo.
  6. Test — Restore power, call for operation, and confirm the contactor pulls in and the load energizes.

Signs You Need a Replacement

  • System won't start even though the board calls for it (contacts not closing)
  • Load runs constantly and won't shut off (welded contacts)
  • Loud buzzing, humming, or chattering from the contactor
  • Visible pitting, burning, or melted housing at the contacts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS120HEAB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS120HEAB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS120HEAB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online