Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS102STAA0AAA – 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS102STAA0AAA – 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp definite purpose contactor (part 1178074) with a 24-volt coil is the electrical relay that switches line voltage to the compressor and fan circuit in the ICP / Tempstar / Heil RGS102STAA0AAA system. When the thermostat calls for cooling, the 24V coil energizes and pulls the contacts closed to deliver power; when the call ends, the contacts open. Over time the contacts pit, burn, weld, or chatter, and the coil can fail open — causing the unit to not start, to short-cycle, or to buzz. A worn contactor is one of the most common no-cool service calls and is an inexpensive, high-value replacement.

Specifications

Spec Value
Part Number 1178074
Type Definite purpose contactor, 2-pole
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2

Compatibility

Fits the ICP RGS102STAA0AAA and other ICP-family (Tempstar, Heil, Comfortmaker) units specifying a 2-pole, 30A, 24V-coil contactor. Confirm pole count, amp rating, and coil voltage against your existing part before ordering.

Installation Guide

  1. Safety First – Disconnect power and verify zero voltage with a multimeter.
  2. Access – Remove the service/electrical panel to reach the contactor.
  3. Document – Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove – Transfer wires one at a time (or label them), unscrew the old contactor from its mount, and remove it.
  5. Install – Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test – Restore power, call for cooling, and confirm the contacts pull in and the unit energizes.

Signs You Need a Replacement

  • Unit won't start or only runs intermittently
  • Loud buzzing, humming, or chattering from the contactor
  • Pitted, blackened, or welded-together contacts
  • Burnt smell or melted housing at the contactor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102STAA0AAA – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102STAA0AAA – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102STAA0AAA – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online