Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS102SRCB0AAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS102SRCB0AAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine ICP OEM contactor, part number 1178074, is a 2-pole, 30-amp electromechanical contactor with a 24V control coil used in the RGS102SRCB0AAA. A contactor is a heavy-duty relay that switches the high-amperage line-voltage circuit feeding major loads. When the 24V coil is energized by the control board or thermostat, an electromagnet pulls the contacts closed, completing the power path; when the coil de-energizes, a spring opens them. Because the contacts make and break under load thousands of times, they eventually pit, burn, or weld. Worn contacts cause hard starts, chattering, dropped voltage, and in severe cases contacts that stick closed and will not let the system shut off. This 30A / 24V coil rating is a direct OEM match, ensuring correct pull-in voltage and contact capacity for your unit.

Specifications

Spec Value
Part Number 1178074
Type Definite purpose contactor
Poles 2
Contact Rating 30 Amps
Coil Voltage 24V AC
Brand ICP / Tempstar / Heil OEM
Fitment OEM direct replacement

Compatibility

Direct replacement for the ICP RGS102SRCB0AAA and shared-platform ICP units (Tempstar, Heil, Comfortmaker, Arcoaire) specifying a 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter on all terminals.
  2. Access — Remove the electrical/control service panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Label and disconnect the wires, unscrew the contactor from its bracket, and remove it.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly with no buzzing and the load energizes.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Chattering or buzzing when the coil energizes
  • System fails to start or starts hard
  • Unit will not shut off because contacts are stuck closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102SRCB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102SRCB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102SRCB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online