Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS102SFCA0AAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS102SFCA0AAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp contactor (part #1178074) is the electrical switch that powers the compressor and condenser fan on your ICP/Tempstar/Heil RGS102SFCA0AAA system. A 24V coil energizes when the thermostat calls for cooling or heating, pulling the contacts closed to deliver line voltage to the compressor. When the coil weakens or the silver contacts pit and burn, you get chattering, intermittent operation, or a complete no-start condition. Replacing a failing contactor is one of the most common HVAC service calls and is critical to protecting the compressor from low-voltage damage.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24V

Compatibility

Fits the ICP Tempstar Heil RGS102SFCA0AAA gas furnace and matched condensing units using a 2-pole 30A definite purpose contactor with a 24V control coil. Always confirm pole count, amp rating, and coil voltage against the part you are replacing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the service panel on the condensing unit or control compartment.
  3. Document — Photograph all wire connections before disconnecting.
  4. Remove — Note line, load, and 24V coil terminals, then transfer wires one at a time or label them; unscrew the old contactor from the mounting bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in cleanly with no chatter.

Signs You Need a Replacement

  • Loud buzzing or chattering from the contactor
  • Compressor or condenser fan won't start or starts intermittently
  • Visibly pitted, burned, or welded contacts
  • Coil hums but contacts fail to pull in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102SFCA0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102SFCA0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102SFCA0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online