This genuine OEM 2-pole, 30-amp contactor with a 24V coil (part number 1178074) is the switching relay that energizes high-voltage loads on the ICP RGS102SFBB0AAA. When the control board calls, the 24V coil pulls in the contacts to send line voltage to the connected load; when the call ends, the contacts open. Contactors are a common failure point because the contacts arc and pit with every cycle. Symptoms of a failing contactor include chattering or buzzing, contacts that weld closed (equipment that won't shut off), burnt or pitted contact faces, and a coil that no longer pulls in. Replacing a worn contactor restores reliable switching and prevents damage to downstream components.

Specifications

Spec Value
Part Number 1178074
Type Contactor, 2-Pole
Brand ICP (Heil / Tempstar / Comfortmaker)
Contact Rating 30 Amp
Coil Voltage 24 VAC
Poles 2
Fitment OEM — direct replacement

Compatibility

Designed for the ICP RGS102SFBB0AAA and compatible Heil, Tempstar, and Comfortmaker units that use a 2-pole 30A / 24V coil contactor. Verify amperage, pole count, and coil voltage against the old part before installing.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage at the contactor terminals with a multimeter.
  2. Access — Remove the service/electrical panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, initiate a call, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Buzzing, humming, or chattering from the contactor
  • Pitted, burnt, or welded contacts
  • Equipment won't shut off (contacts stuck closed)
  • Coil won't pull in even with 24V present

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102SFBB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102SFBB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102SFBB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online