Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS102SEAB0AAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS102SEAB0AAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole 30-amp contactor (part number 1178074) with a 24V coil is the load-switching relay for the ICP RGS102SEAB0AAA system. When the thermostat calls and the control board energizes the 24V coil, the contactor pulls in and closes its two 30A power contacts to feed line voltage to the compressor and condenser fan motor. As the most frequently cycled high-current component, the contactor is a common wear item: its contacts pit, burn, and stick over time. Symptoms of a failing contactor include the unit not starting, contacts that buzz or hum loudly, pitted or welded contacts that keep the compressor running after the call ends, or an open 24V coil that produces no pull-in.

Specifications

Spec Value
Part Number 1178074
Type Contactor, 2-Pole
Contact Rating 30A
Coil Voltage 24V
Poles 2
Brand ICP (Tempstar / Heil / Comfortmaker)
Fits Model RGS102SEAB0AAA
Fitment OEM Direct Replacement

Compatibility

This 2-pole 30A 24V contactor is the OEM-specified switching device for the ICP RGS102SEAB0AAA system and matching ICP-built Tempstar, Heil, and Comfortmaker equipment. Verify pole count, amp rating, and 24V coil voltage against your original before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical-access service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Label and disconnect the wires, remove the mounting screws, and take out the old contactor.
  5. Install — Mount the new contactor and reconnect each line, load, and 24V coil wire per your photo.
  6. Test — Restore power and call for cooling; confirm a firm pull-in click and proper compressor/fan operation.

Signs You Need a Replacement

  • Unit will not start despite a valid cooling call.
  • Loud buzzing or humming from the contactor.
  • Pitted, burned, or welded contacts that keep the compressor running.
  • No pull-in and no continuity across the 24V coil when energized.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102SEAB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102SEAB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102SEAB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera