Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS102LSAA0AAA – 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS102LSAA0AAA – 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp contactor with a 24-volt coil (part 1178074) for the ICP / Tempstar / Heil RGS102LSAA0AAA system is the electromechanical switch that powers the compressor and condenser fan. When the thermostat calls for cooling, 24V energizes the coil, pulling the contacts closed to deliver line voltage to the loads. Contactors fail from arcing, pitted or welded contacts, burned coils, and insects nesting under the armature. Symptoms include a system that won't start, contacts that chatter or buzz, a compressor that won't shut off (welded contacts), and visible burning or pitting on the contact faces.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Fitment OEM

Compatibility

Fits the ICP / Tempstar / Heil / Comfortmaker RGS102LSAA0AAA and other systems specifying a 2-pole 30A 24V definite-purpose contactor. Verify pole count, amp rating, and coil voltage against your old part.

Installation Guide

  1. Safety First – Disconnect power at the disconnect and breaker; verify zero voltage at the contactor terminals with a multimeter.
  2. Access – Remove the control/electrical service panel.
  3. Document – Photograph all line, load, and coil wiring before disconnecting.
  4. Remove – Transfer wires one at a time or label them, then unscrew the old contactor from its mount.
  5. Install – Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test – Restore power, call for cooling, and confirm the contacts pull in and the compressor/fan energize.

Signs You Need a Replacement

  • System won't start on a cooling call
  • Buzzing, chattering, or humming at the contactor
  • Compressor runs continuously (welded contacts)
  • Pitted, burned, or corroded contact faces

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102LSAA0AAA – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102LSAA0AAA – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102LSAA0AAA – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera