This OEM 2-pole 30-amp definite-purpose contactor (part 1178074) with a 24-volt coil is the power-switching relay for the ICP Tempstar Heil RGS102HTCB0AAA system. When the thermostat calls for cooling, the 24V coil pulls the contacts closed and energizes the compressor and condenser fan; when the call ends, it drops out and cuts line power. Contactors are high-wear parts — the contacts arc and pit with every cycle. Failure symptoms include a unit that won't start, chattering or buzzing at the contactor, contacts that weld closed (so the compressor never shuts off), or visible burning and pitting on the contact points.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC
Fitment OEM Replacement

Compatibility

Fits the ICP Tempstar Heil RGS102HTCB0AAA and a wide range of ICP-family condensing units and air handlers calling for a 2-pole, 30A, 24V-coil contactor. Verify amp rating and coil voltage against the original before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph every line, load, and coil wire before disconnecting.
  4. Remove — Unfasten the old contactor and transfer wires one at a time, or label each lead.
  5. Install — Mount the new contactor, reconnect line, load, and 24V coil leads per your photo, and confirm tight terminals.
  6. Test — Restore power and verify the contactor pulls in on a cooling call and drops out cleanly when satisfied.

Signs You Need a Replacement

  • Unit won't start or starts intermittently
  • Loud chattering or buzzing from the contactor
  • Contacts welded closed — compressor runs continuously
  • Burned, pitted, or melted contact points

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102HTCB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102HTCB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102HTCB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online