Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS102HTBB0AAA — 24V Coil OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS102HTBB0AAA — 24V Coil OEM 1178074 | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

Genuine OEM 2-pole, 30-amp contactor with a 24V coil (part #1178074) for the ICP / Tempstar / Heil RGS102HTBB0AAA system. The contactor is the electrically controlled switch that energizes the high-voltage load when the 24V control signal calls for operation. Over time the contacts pit, weld, or burn, and the coil can fail open — causing the system to fail to start, chatter, or stay energized when it should be off. This two-pole, 30A device switches both legs of the line voltage from a single 24V coil.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Fits Model RGS102HTBB0AAA
Fitment OEM Direct Replacement

Compatibility

Built for the ICP-family RGS102HTBB0AAA system (Tempstar, Heil, Comfortmaker and related ICP brands). Confirm 2-pole, 30A, 24V coil and part number 1178074 against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the switch and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph all line, load, and coil connections before disconnecting any wires.
  4. Remove — Label and disconnect each terminal, then unscrew and remove the old contactor.
  5. Install — Mount the new contactor and reconnect every wire exactly per your photos.
  6. Test — Restore power and confirm the contactor pulls in cleanly and switches the load with no chatter or buzzing.

Signs You Need a Replacement

  • System won't start or starts intermittently
  • Loud chattering or buzzing from the contactor
  • Pitted, welded, or burnt contacts
  • Load stays energized after the call ends (stuck contacts)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102HTBB0AAA — 24V Coil OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102HTBB0AAA — 24V Coil OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102HTBB0AAA — 24V Coil OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online