Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS102HSBB0AAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS102HSBB0AAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole contactor (part #1178074) is a 30-amp, 24-volt-coil switching relay used in ICP, Heil, and Tempstar equipment including the RGS102HSBB0AAA. The contactor energizes when the 24V control circuit calls for operation, closing its main contacts to pass line voltage to the connected load. Over time the silver-plated contacts pit, arc, and weld together from repeated inrush current. Common failure symptoms include a unit that won't start, chattering or buzzing from the contactor, contacts that stick closed (equipment runs continuously), or visible burning and corrosion on the terminals.

Specifications

Spec Value
Part Number 1178074
Type 2-Pole Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2
Fitment OEM

Compatibility

Engineered as the factory replacement for the ICP/Heil/Tempstar RGS102HSBB0AAA and shared across many ICP-family gas furnace and condensing units that use a 30A/24V 2-pole contactor. Confirm your existing contactor is a 2-pole, 30A, 24V-coil unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and service disconnect, then verify zero voltage with a multimeter at the contactor terminals.
  2. Access — Remove the unit's service panel to expose the control box.
  3. Document — Photograph all wire connections before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from its mounting bracket.
  5. Install — Mount the new contactor, reconnect each wire exactly per your photo, and confirm tight terminals.
  6. Test — Restore power and verify the contactor pulls in cleanly with no chatter when a call is initiated.

Signs You Need a Replacement

  • Audible buzzing, humming, or chattering during operation
  • Equipment fails to start or starts intermittently
  • Contacts welded closed so the unit will not shut off
  • Pitted, burned, or corroded contact surfaces

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102HSBB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102HSBB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102HSBB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online