Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS102HFAA0AAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS102HFAA0AAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite-purpose contactor (OEM part 1178074) is the electromechanical switch that powers the major loads in your ICP RGS102HFAA0AAA system. Rated at 30 amps with a 24-volt coil, it energizes when the thermostat calls for cooling or heating, pulling its contacts closed to feed line voltage to the compressor and condenser fan motor. Contactors are high-wear items: their silver contacts arc every time they open and close, eventually pitting, welding, or burning. Common failure symptoms include a system that won't start, a humming or chattering contactor, contacts that stick closed (equipment runs constantly), or visible burning and melted housing. Replacing a worn contactor restores reliable switching and prevents damage to the more expensive compressor it protects.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC

Compatibility

Directly fits the ICP RGS102HFAA0AAA and the matching Tempstar, Heil, and Comfortmaker furnace and air-handler platforms that share this 2-pole 30A 24V control architecture. Always confirm the existing contactor's amp and coil rating against your unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the unit disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel to expose the control box.
  3. Document — Photograph all wire positions before disconnecting anything.
  4. Remove — Note the line, load, and coil (24V) terminals, transfer one wire at a time, then unscrew the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire to the identical terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly and the equipment energizes.

Signs You Need a Replacement

  • System fails to start or starts intermittently
  • Loud humming, buzzing, or chattering from the contactor
  • Contacts stuck closed so the unit runs nonstop
  • Pitted, burned, or melted contacts and housing

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS102HFAA0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS102HFAA0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS102HFAA0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online