Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS101SFBA0AAAA - 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS101SFBA0AAAA - 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp contactor (part #1178074) with a 24V coil switches the high-voltage compressor and fan loads in your ICP/Tempstar/Heil RGS101SFBA0AAAA system. When the thermostat calls, the 24V control signal energizes the contactor coil, pulling the two main contacts closed to power the equipment. Contactors are high-wear components: their contacts pit and burn from the arcing of repeated switching. A failed contactor is a leading cause of a unit that hums but won't start, or one that won't shut off. This is a direct OEM-spec 30A / 24V replacement.

Specifications

Spec Value
OEM Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Fitment OEM direct replacement

Compatibility

Engineered for the ICP Tempstar Heil RGS101SFBA0AAAA system and related models using the 1178074 contactor. Verify your OEM part number and coil voltage before ordering.

Installation Guide

  1. Safety First - Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access - Remove the electrical access panel.
  3. Document - Photograph all line, load, and 24V coil connections before disconnecting.
  4. Remove - Label and disconnect the wires, then remove the mounting screws and the old contactor.
  5. Install - Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test - Restore power, run a cooling cycle, and confirm the contacts pull in and the unit starts.

Signs You Need a Replacement

  • Unit hums or buzzes but won't start
  • Pitted, burnt, or welded contacts
  • System won't shut off (stuck contacts)
  • Buzzing or chattering from the contactor coil

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS101SFBA0AAAA - 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS101SFBA0AAAA - 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS101SFBA0AAAA - 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online