This OEM 2-pole, 30-amp contactor (part #1178074) with a 24V coil is the primary switching relay for the ICP/Tempstar/Heil RGS101SECB0AAA. When the thermostat calls and the 24V coil energizes, the contactor pulls in its two power poles to deliver line voltage to the compressor and condenser fan. Contactors endure thousands of high-current cycles, so the contacts pit, burn, and weld over time, and the coil can lose its pull. Common failure symptoms include a unit that won't start, contacts buzzing or chattering, points welded closed so the system runs continuously, or visible arcing, pitting, and burnt terminals on the contact faces.

Specifications

Spec Value
Part Number 1178074
Type 2-Pole Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Rating 30A
Coil Voltage 24V
Poles 2
Fitment OEM Direct Replacement

Compatibility

Direct OEM replacement for the 2-pole 30A 24V-coil contactor in the ICP/Tempstar/Heil RGS101SECB0AAA. Confirm pole count, amp rating, and 24V coil on your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the service panel to expose the contactor.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Label and disconnect each wire, then unscrew the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect every wire to the matching terminal per your photo.
  6. Test — Restore power and call for cooling; confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Compressor or condenser fan won't start on a call for cooling
  • Buzzing or chattering from the contactor
  • Contacts welded closed, leaving the unit running constantly
  • Visible pitting, arcing, or burnt terminals on the contacts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS101SECB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS101SECB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS101SECB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.