This genuine OEM 2-pole, 30-amp definite purpose contactor (part number 1178074) with a 24-volt coil is the switching relay for the ICP/Heil/Tempstar RGS101LFAA0AAAA. When the thermostat calls for cooling or heat-pump operation, the 24V coil energizes and pulls the contacts closed, sending line voltage to the compressor and condenser fan motor. Contactors fail from arcing, pitted or welded contacts, an open coil, or stuck plungers caused by insects and debris. Symptoms include a system that won't start, chattering or buzzing at the contactor, or a compressor that runs continuously. Installing the factory contactor restores reliable, clean switching.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor, 2-Pole
Brand ICP / Heil / Tempstar
Contact Rating 30A
Coil Voltage 24V
Poles 2
Fits Model RGS101LFAA0AAAA

Compatibility

Direct OEM fit for the ICP RGS101LFAA0AAAA and equivalent ICP/Heil/Tempstar/Comfortmaker units specifying a 2-pole 30A 24V coil contactor (part 1178074). Verify amp rating, pole count, and coil voltage against your existing part.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage with a multimeter across the line terminals.
  2. Access — Remove the unit's electrical access panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Transfer wires one at a time or label them, unscrew the old contactor from its mount, and remove it.
  5. Install — Mount the new contactor, reconnect each wire to the matching terminal per your photo, and confirm tight connections.
  6. Test — Restore power, call for cooling, and verify the contacts pull in and the compressor and fan energize.

Signs You Need a Replacement

  • System won't start or only starts intermittently
  • Loud buzzing, humming, or chattering at the contactor
  • Visibly pitted, burned, or welded contacts
  • Compressor runs continuously because contacts won't open

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS101LFAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS101LFAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS101LFAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.