Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS091STCB0AAA — 24V Coil OEM | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS091STCB0AAA — 24V Coil OEM | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM 2-pole, 30-amp definite purpose contactor with a 24-volt coil (OEM #1178074) for the ICP / Heil / Tempstar RGS091STCB0AAA. The contactor is the electrically operated switch that energizes the compressor and condenser fan whenever the thermostat calls for cooling — the 24V control coil pulls the contacts closed to pass line voltage to the load. Over thousands of cycles the contacts pit and burn and the coil weakens, causing the system to chatter, fail to start, or refuse to stop. Replacing the contactor restores reliable, clean switching.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC
Fits Model RGS091STCB0AAA
Application Compressor / Condenser Fan Switching

Compatibility

Direct OEM fit for the ICP / Heil / Tempstar RGS091STCB0AAA. Confirm pole count, amp rating, and 24V coil match your existing contactor.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unmount the old contactor.
  5. Install — Mount the new 2-pole contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cool call and drops out cleanly.

Signs You Need a Replacement

  • Buzzing or chattering contactor that won't seat
  • Pitted, burned, or welded contacts
  • AC won't start, or won't shut off after the call ends
  • Visible arcing or melted terminals

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091STCB0AAA — 24V Coil OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091STCB0AAA — 24V Coil OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091STCB0AAA — 24V Coil OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart