This is a genuine OEM 2-pole definite-purpose contactor (OEM part number 1178074) rated at 30 amps with a 24-volt coil, built for ICP/Tempstar/Heil equipment including model RGS091LTAB0AAAA. A contactor is the electrically operated switch that energizes the high-voltage load when the 24V control circuit calls for operation. When the coil receives 24V from the control board or thermostat circuit, the electromagnet pulls the contacts closed and power flows to the connected load. Worn, pitted, or welded contacts are one of the most common HVAC failures — they cause hard starting, chattering, intermittent operation, or a unit that will not start at all. Replacing a failing contactor with the correct OEM 2-pole 30A 24V part restores reliable switching and protects downstream components from voltage drop and arcing.

Specifications

Spec Value
OEM Part Number 1178074
Type Definite-Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Fits Model RGS091LTAB0AAAA

Compatibility

This OEM contactor is designed for ICP-family equipment (Tempstar, Heil, Comfortmaker, Arcoaire) and is a direct fit for model RGS091LTAB0AAAA. Always confirm the existing part carries number 1178074 or a listed superseding number, and verify the coil is 24V and the contacts are rated 30A before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and the unit disconnect. Verify zero voltage at the contactor terminals with a multimeter before touching any wiring.
  2. Access — Remove the service / electrical access panel to expose the contactor.
  3. Document — Photograph every wire and terminal position before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from its bracket.
  5. Install — Mount the new 1178074 contactor, reconnect each wire to the matching terminal per your photo, and confirm the coil leads land on the 24V terminals.
  6. Test — Restore power, call for operation, and confirm the contactor pulls in cleanly with no chatter and full voltage across the load.

Signs You Need a Replacement

  • Buzzing, chattering, or humming from the contactor when energized
  • Pitted, blackened, or welded-together contacts
  • Unit fails to start or starts intermittently
  • Coil does not pull the contacts in even with 24V present

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091LTAB0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091LTAB0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091LTAB0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online