This OEM 2-pole, 30-amp definite-purpose contactor (part 1178074) with a 24-volt coil is the primary switching relay for the ICP Tempstar/Heil RGS091LTAA0AAAA system. When the thermostat calls and the 24V control circuit energizes the coil, the contactor pulls in and closes both pole sets, sending line voltage to the compressor and condenser fan motor. Rated for 30A across two poles, it handles the high inrush of compressor starts thousands of times per season. Contacts eventually pit, weld, or chatter from arcing — symptoms include a humming or buzzing contactor, the outdoor unit not starting, or contacts that stick closed and run the unit continuously.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor, 2-Pole
Brand ICP (Tempstar / Heil)
Contact Rating 30A
Coil Voltage 24V
Poles 2
Application Compressor / Condenser Fan Switching
Fitment OEM

Compatibility

Fits the ICP Tempstar/Heil RGS091LTAA0AAAA and other units specifying a 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical-panel cover on the unit.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time, then unscrew the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the unit starts.

Signs You Need a Replacement

  • Loud humming or buzzing from the contactor
  • Pitted, burned, or welded contacts
  • Outdoor unit won't start or won't shut off
  • Visible arcing or chattering when energized

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091LTAA0AAAA — 24V Coil OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091LTAA0AAAA — 24V Coil OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091LTAA0AAAA — 24V Coil OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online