Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS091LRCB0AAA — 24V Coil OEM | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS091LRCB0AAA — 24V Coil OEM | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (part 1178074) for the ICP / Tempstar / Heil RGS091LRCB0AAA system. The contactor is the electrically controlled switch that delivers line voltage to the compressor and condenser fan motor whenever the thermostat calls for cooling. The 24V coil is energized by the low-voltage control circuit, pulling the contacts closed to power the high-voltage components. Contactors wear out from arcing, pitting, and corrosion on the contact points — a failed contactor is one of the most common causes of an outdoor unit that hums but won't start, or a system that won't shut off.

Specifications

Spec Value
Part Number 1178074
Type 2-Pole Contactor
Brand ICP / Tempstar / Heil
Rating 30 Amps
Coil Voltage 24V
Poles 2

Compatibility

Direct-fit for the ICP RGS091LRCB0AAA and related ICP, Tempstar, Heil, Comfortmaker, and Arcoaire systems that use a 2-pole 30A 24V-coil contactor. Confirm pole count, amp rating, and coil voltage against your existing part before ordering.

Installation Guide

  1. Safety First — Disconnect power at the unit and verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph every wire on the line, load, and coil terminals before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew and remove the old contactor.
  5. Install — Mount the new contactor, reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in on a cooling call and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but compressor/fan won't start
  • Burned, pitted, or welded contacts
  • Chattering contactor or system that won't cycle off
  • Visible arcing, melted housing, or corrosion on the contacts

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091LRCB0AAA — 24V Coil OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091LRCB0AAA — 24V Coil OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091LRCB0AAA — 24V Coil OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online