This OEM 2-pole, 30-amp contactor with a 24-volt coil (part 1178074) is the electrical switch that energizes the load on your ICP Tempstar/Heil RGS091LFBA0AAAA system. When the control circuit applies 24V to the coil, the contactor's electromagnet pulls the contacts closed and passes line voltage through to the connected components; when the call ends, the coil de-energizes and the contacts open. Contactors are wear items — repeated arcing pits and burns the contacts, the coil can fail open, and the contacts can weld shut so the equipment runs continuously. Replacing a worn contactor restores clean switching and protects downstream components.

Specifications

Spec Value
Part Number 1178074
Type 2-Pole Definite Purpose Contactor
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2
Brand ICP / Tempstar / Heil
Fitment OEM Direct Replacement

Compatibility

Fits the ICP Tempstar Heil RGS091LFBA0AAAA and equivalent ICP-family equipment (Tempstar, Heil, Comfortmaker, Arcoaire) calling for a 2-pole 30A contactor with a 24V coil. Confirm pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect electrical power at the disconnect or breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control compartment service panel.
  3. Document — Photograph every wire and its terminal before disconnecting.
  4. Remove — Transfer wires one at a time or label them, unbolt the old contactor, and remove it.
  5. Install — Mount the new 30A contactor, reconnect line, load, and 24V coil leads exactly per your photo.
  6. Test — Restore power, initiate a call, and confirm the contactor pulls in firmly and passes voltage to the load.

Signs You Need a Replacement

  • Loud chattering or buzzing from the contactor when energized
  • Pitted, burned, or welded contacts
  • Equipment runs constantly because contacts are stuck closed
  • No operation despite a 24V signal at the coil (open coil)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091LFBA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091LFBA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091LFBA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.