Overview

This is a genuine OEM 2-pole definite purpose contactor (part #1178074) for the ICP / Tempstar / Heil RGS091LECA0AAA. The contactor is the electromagnetic switch that energizes the high-voltage circuit when the 24V control signal calls for operation. Rated for 30 amps with a 24-volt coil, it carries line voltage to the connected load and drops out when the call ends. Failed contactors are one of the most common HVAC service items: contacts pit, weld shut, or chatter from arcing over thousands of cycles. Symptoms include a unit that won't start, a humming or buzzing relay, contacts that stay closed so the equipment never shuts off, or visible burning/pitting on the contact faces.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Amp Rating 30A
Coil Voltage 24V
Poles 2
Fit OEM Direct Replacement

Compatibility

Direct OEM fit for the ICP RGS091LECA0AAA. The same 2-pole 30A 24V contactor is used across many ICP-family furnaces and condensing units sold under the Tempstar, Heil, Comfortmaker, and Arcoaire brands. Always confirm your existing contactor's pole count, amp rating, and coil voltage before ordering.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the service/control panel to expose the contactor.
  3. Document — Photograph all line and coil wiring before disconnecting anything.
  4. Remove — Label and remove the line, load, and 24V coil wires, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor, transfer wiring per your photo, confirm tight terminals.
  6. Test — Restore power, initiate a call, and verify the contactor pulls in cleanly and drops out on demand.

Signs You Need a Replacement

  • Pitted, burned, or welded contact surfaces
  • Loud buzzing or chattering when energized
  • Equipment won't start even though the coil is getting 24V
  • Unit won't shut off because contacts are stuck closed

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091LECA0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091LECA0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091LECA0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.