This genuine OEM 2-pole, 30-amp contactor (part number 1178074) is the switching relay for the ICP/Heil/Tempstar RGS091LDBB0AAAA system. Its 24-volt control coil is energized by the thermostat circuit; when energized, the contactor closes its two power poles to feed line voltage to the compressor and condenser fan motor. Contactors are high-wear parts — the contacts pit, burn, and weld over thousands of cycles. Pitted contacts cause hard starts, chatter, and intermittent cooling, while welded contacts can leave the compressor running continuously. Replacing a worn contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP / Heil / Tempstar / Comfortmaker
Fits Model RGS091LDBB0AAAA

Compatibility

Factory-correct switching contactor for the RGS091LDBB0AAAA and other ICP-platform units calling for a 2-pole, 30A, 24V-coil definite-purpose contactor. Shared across the ICP, Heil, Tempstar, and Comfortmaker badge family. Confirm pole count, contact amperage, and coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the breaker and disconnect, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel to expose the contactor.
  3. Document — Photograph every wire and terminal location before disconnecting.
  4. Remove — Transfer wires one at a time to the new contactor, or label them, then unbolt the old contactor.
  5. Install — Mount the new 1178074, reconnect all line, load, and 24V coil wires per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor energizes.

Signs You Need a Replacement

  • Buzzing, chattering, or humming from the contactor
  • Pitted, blackened, or welded contact points
  • Compressor that won't start or runs continuously
  • Intermittent cooling or repeated hard starts

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS091LDBB0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS091LDBB0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS091LDBB0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.