Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS090STAA0AGAA - 24V Coil OEM | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS090STAA0AGAA - 24V Coil OEM | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM 2-pole, 30-amp definite purpose contactor (part number 1178074) with a 24V control coil for the ICP / Tempstar / Heil RGS090STAA0AGAA system. The contactor is the high-current switch that energizes the compressor and condenser fan when the 24-volt control signal pulls in the coil. Pitted or welded contacts, a burnt or open coil, or a chattering armature are classic contactor failures that cause a no-cooling call, a humming outdoor unit that will not start, or a unit that runs continuously. The exact OEM 30A / 24V contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fit OEM Direct Replacement

Compatibility

Direct-fit OEM replacement for the ICP / Tempstar / Heil RGS090STAA0AGAA. A 2-pole, 30A contactor with a 24V coil; confirm the 1178074 part number, pole count, and coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First - Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access - Remove the control/electrical access panel on the unit.
  3. Document - Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove - Transfer wires one at a time or label them, then unbolt the old contactor.
  5. Install - Mount the new 1178074 contactor and reconnect each wire exactly per your photos.
  6. Test - Restore power and confirm the contactor pulls in and the compressor and fan start on a cooling call.

Signs You Need a Replacement

  • Outdoor unit hums but the compressor and fan will not start
  • Pitted, burnt, or welded-shut contacts
  • Loud chattering or buzzing from the contactor
  • Unit runs continuously and will not shut off, or no 24V pull-in

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS090STAA0AGAA - 24V Coil OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS090STAA0AGAA - 24V Coil OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS090STAA0AGAA - 24V Coil OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online