Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS090SEBA0AGAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS090SEBA0AGAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp contactor with a 24V coil (part 1178074) is the primary power-switching relay for the ICP/Heil/Tempstar RGS090SEBA0AGAA system. When the thermostat calls and energizes the 24V coil, the contactor pulls in and sends line voltage to the compressor and condenser fan motor. Contactors are high-wear components — the contacts pit, burn, and weld over thousands of cycles, while ants and debris can jam the armature. A failed contactor causes a no-cool condition, chattering, or a unit that runs continuously and will not shut off. This genuine OEM 30A contactor restores reliable, safe switching with the correct coil voltage and contact rating.

Specifications

Spec Value
Part Number 1178074
Type 2-Pole Definite Purpose Contactor
Brand ICP / Heil / Tempstar
Contact Rating 30 Amps
Coil Voltage 24V
Poles 2
Fit OEM Replacement

Compatibility

Designed for the ICP family RGS090SEBA0AGAA system and widely shared across Heil, Tempstar, Comfortmaker, and Arcoaire condensing units using a 2-pole 30A 24V contactor. Confirm the pole count, amp rating, and coil voltage match your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser access panel to expose the contactor in the control box.
  3. Document — Photograph every line, load, and coil wire position before disconnecting.
  4. Remove — Label and remove each wire, unscrew the mounting, and lift out the old contactor.
  5. Install — Mount the new contactor and transfer each wire to the matching terminal per your photos, confirming the 24V coil leads are correct.
  6. Test — Restore power and trigger a cooling call, verifying the contactor pulls in cleanly and the compressor and fan energize.

Signs You Need a Replacement

  • System does not cool and the contactor will not pull in
  • Loud buzzing or chattering from the contactor
  • Pitted, burned, or welded contacts
  • Compressor runs continuously and will not shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS090SEBA0AGAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS090SEBA0AGAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS090SEBA0AGAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online