Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS090LTCB0AAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS090LTCB0AAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (part number 1178074) is the switching relay that energizes the high-voltage components in your ICP / Tempstar / Heil RGS090LTCB0AAA system. When the thermostat calls, the 24V control signal pulls in the contactor, closing both poles and sending line voltage to the compressor and condenser fan. Pitted or burned contacts, a chattering or dead coil, or welded points are the most common causes of a system that won't start, hums but won't run, or short cycles. A fresh contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1178074
Type Definite-purpose contactor, 2-pole
Brand ICP (Tempstar / Heil)
Contact Rating 30 Amps
Poles 2
Coil Voltage 24 VAC
Fitment OEM factory replacement

Compatibility

Direct fit for the ICP RGS090LTCB0AAA and other ICP-family units (Tempstar, Heil, Comfortmaker) that use a 30A 2-pole 24V contactor. Confirm your existing contactor's amp and coil ratings before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter across the contactor terminals.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph all wiring at the contactor before disconnecting.
  4. Remove — Label and remove the line, load, and 24V coil wires, then unscrew the old contactor from the mounting plate.
  5. Install — Mount the new contactor and transfer each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm both poles pull in and the compressor and fan energize.

Signs You Need a Replacement

  • Burned, pitted, or welded contacts
  • Loud buzzing or chattering from the contactor
  • System hums but compressor won't start
  • Intermittent operation or short cycling

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS090LTCB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS090LTCB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS090LTCB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online