Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor for RGS090LSCB0AAA — 24V Coil OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A Contactor for RGS090LSCB0AAA — 24V Coil OEM 1178074 | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp definite-purpose contactor (Part #1178074) with a 24-volt coil is the switching relay for the ICP / Tempstar / Heil RGS090LSCB0AAA system. When the thermostat or control board energizes the 24V coil, the contactor pulls in and closes its 30A line-voltage contacts to power the connected load. Over time the contacts pit, arc, and weld, or the coil fails — causing the unit to fail to start, chatter, or stay running after the call ends. A fresh contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor, 2-Pole
Brand ICP / Tempstar / Heil
Contact Rating 30 Amps
Coil Voltage 24 VAC
Poles 2
Fits Model RGS090LSCB0AAA
Fitment OEM exact-fit

Compatibility

Direct-fit replacement for the ICP, Tempstar, Heil, Comfortmaker, and Arcoaire RGS090LSCB0AAA and compatible RGS090 series units calling for a 2-pole 30A / 24V contactor. Verify your existing coil voltage and amp rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker. Verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Move wires one at a time to the new contactor, or label them, then unscrew the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect each wire per your photo, confirming line and coil (24V) terminals.
  6. Test — Restore power, initiate a call, and confirm the contactor pulls in cleanly and the load energizes.

Signs You Need a Replacement

  • Burnt, pitted, or welded contacts
  • Loud chattering or buzzing at the contactor
  • Unit won't start even with a 24V signal at the coil
  • Contactor stays pulled in after the call ends

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS090LSCB0AAA — 24V Coil OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS090LSCB0AAA — 24V Coil OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS090LSCB0AAA — 24V Coil OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online