Overview

This OEM 2-pole 30-amp definite-purpose contactor (part number 1178074) is the switching relay for the ICP/Tempstar/Heil RGS090LSBB0AAA system. The 24-volt coil energizes when the thermostat calls, pulling the contacts closed to deliver line voltage to the connected load. Contactors are among the most common HVAC failure points: the silver contacts pit and burn from repeated arcing, and the coil can fail open. Symptoms include a unit that won't start, chattering or buzzing from the contactor, or contacts that weld shut and leave the system running continuously. This factory-spec part restores reliable switching with rated 30A contacts and a 24V control coil.

Specifications

Spec Value
Part Number 1178074
Type Definite-Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24 VAC
Brand ICP (Tempstar / Heil / Comfortmaker)

Compatibility

Direct OEM fit for the ICP RGS090LSBB0AAA and equivalent Tempstar, Heil, and Comfortmaker platform models. Confirm pole count and coil voltage against the contactor you are replacing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph all line, load, and coil wires before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for operation, and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Unit fails to start or starts intermittently
  • Loud buzzing, humming, or chattering from the contactor
  • Pitted, burned, or welded contacts
  • System runs continuously and won't shut off

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS090LSBB0AAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS090LSBB0AAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS090LSBB0AAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online