This is the genuine OEM 2-pole, 30-amp definite purpose contactor with a 24-volt coil, ICP part number 1178074, for the ICP/Tempstar/Heil RHS120S0CA0AAA heat pump. The contactor is the high-voltage switch that powers the compressor and outdoor fan motor whenever the 24V control circuit calls for cooling or heating. Its contacts carry heavy load and arc on every cycle, so they eventually pit, weld, or burn. A failing contactor causes hard starts, chatter, a humming outdoor unit that won't run, or a compressor that won't shut off. This OEM 30A 2-pole replacement restores reliable switching.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Application Compressor / condenser fan

Compatibility

Fits the ICP/Tempstar/Heil RHS120S0CA0AAA heat pump and other RHS120 series units specifying a 2-pole 30A 24V contactor. Confirm pole count, amp rating, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage across all line terminals with a multimeter.
  2. Access — Remove the outdoor unit electrical panel.
  3. Document — Photo every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time, then unscrew and lift out the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor/fan energize cleanly.

Signs You Need a Replacement

  • Outdoor unit hums but compressor and fan won't start
  • Buzzing, chattering, or clicking at the contactor
  • Pitted, burned, or welded contacts
  • Compressor that won't shut off (stuck contacts)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS120S0CA0AAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS120S0CA0AAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS120S0CA0AAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.