Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor 24V for RHH102S0CA0AAAA — OEM | Ships Today
ICP

ICP 2-Pole 30A Contactor 24V for RHH102S0CA0AAAA — OEM | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the genuine OEM ICP 2-pole, 30-amp contactor with a 24V coil, part number 1178074 (CONTACTOR 2P 30A 24V), for the RHH102S0CA0AAAA heat pump. The contactor is the high-voltage switch that powers the compressor and outdoor fan motor whenever the thermostat calls. Its 24V coil pulls the contacts closed; pitted, burned, or chattering contacts cause hard starts, no-cool/no-heat conditions, buzzing, or a unit that won't shut off. A fresh OEM 30A contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1178074
Description Contactor, 2-Pole, 30A, 24V Coil
Type 2-Pole Definite Purpose Contactor
Brand ICP
Contact Rating 30A
Coil Voltage 24V
Poles 2
Fitment OEM

Compatibility

Direct-fit for the ICP / Tempstar / Heil RHH102S0CA0AAAA heat pump and other units specifying a 2-pole 30A 24V contactor. Verify amp rating, pole count, and coil voltage against your unit before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the condenser electrical access panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Note line/load and 24V coil leads, disconnect them, and unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contacts pull in and the compressor/fan energize on a call.

Signs You Need a Replacement

  • Buzzing or chattering at the outdoor unit
  • Burned, pitted, or welded contacts
  • Compressor/fan won't start or won't shut off
  • Coil won't pull the contacts in on a 24V call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHH102S0CA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHH102S0CA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHH102S0CA0AAAA — OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.