Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor 24V for RGS240SEAA0AAAA — OEM 1171554 | Ships Today
ICP

ICP 2-Pole 30A Contactor 24V for RGS240SEAA0AAAA — OEM 1171554 | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

The 1171554 is the OEM 2-pole, 30-amp contactor with a 24V coil for the ICP/Tempstar/Heil RGS240SEAA0AAAA. The contactor is the electrical switch that energizes the compressor and condenser fan motor when the thermostat calls for cooling. Over time the contacts pit, burn, or weld from the constant high-current arcing, and the 24V coil can fail open. Symptoms include a system that won't start, a humming contactor that won't pull in, or a compressor that won't shut off. A fresh contactor restores clean, reliable switching.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30A
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fitment OEM Direct-Fit

Compatibility

Built for the ICP/Tempstar/Heil RGS240SEAA0AAAA and other models using a 2-pole 30A 24V-coil contactor. Verify pole count, amp rating, and coil voltage against your existing part.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photo all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time, or label them, then unscrew the old contactor.
  5. Install — Mount the new contactor and reconnect each wire per your photo.
  6. Test — Restore power and confirm the contactor pulls in and the compressor/fan start on a cooling call.

Signs You Need a Replacement

  • System won't start on a cooling call
  • Loud buzzing or chattering from the contactor
  • Burned, pitted, or welded contacts
  • Compressor runs continuously and won't drop out

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS240SEAA0AAAA — OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS240SEAA0AAAA — OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS240SEAA0AAAA — OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online