Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor 24V Coil for RHS181H0CA0AAAA — Compressor Control | Ships Today
ICP

ICP 2-Pole 30A Contactor 24V Coil for RHS181H0CA0AAAA — Compressor Control | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole 30-amp contactor with a 24V coil is the main switching relay for the ICP / Tempstar / Heil RHS181H0CA0AAAA heat pump. When the thermostat calls, the 24V coil pulls the contacts closed and sends line voltage to the compressor and condenser fan motor. Over thousands of cycles the silver contacts pit and burn, leading to a chattering contactor, welded contacts that won't drop out, or a unit that won't start at all. This OEM-spec contactor (related part 1171554; 3-pole 40A 1172449 also available) restores reliable, clean switching.

Specifications

Spec Value
OEM Part Numbers 1171554 (2P 30A 24V), 1172449 (3P 40A 24V)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2
Contact Rating 30 Amps
Coil Voltage 24V

Compatibility

Designed for the ICP-family RHS181H0CA0AAAA 1.5-ton heat pump and matching Tempstar, Heil, Comfortmaker, and Arcoaire units. Confirm pole count, contact amperage, and coil voltage against your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel to expose the contactor.
  3. Document — Photograph every line, load, and 24V coil lead before disconnecting.
  4. Remove — Transfer the leads one at a time or label them, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor, land line voltage on L1/L2, load on T1/T2, and the 24V leads on the coil terminals per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a thermostat call and drops out fully when satisfied.

Signs You Need a Replacement

  • Loud buzzing or chattering from the contactor
  • Pitted, burnt, or welded contacts
  • Compressor and fan won't start on a cooling call
  • Unit won't shut off because contacts are stuck closed

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns on unused parts. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS181H0CA0AAAA — Compressor Control | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS181H0CA0AAAA — Compressor Control | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS181H0CA0AAAA — Compressor Control | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart