Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor 24V Coil for RHH060L0BA0AAAA – OEM 1178074 | Ships Today
ICP

ICP 2-Pole 30A Contactor 24V Coil for RHH060L0BA0AAAA – OEM 1178074 | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp contactor with a 24V coil (ICP part number 1178074) is the main switching relay for the ICP/Tempstar/Heil RHH060L0BA0AAAA heat pump. When the thermostat sends a 24-volt call, the coil pulls the contacts closed and feeds line power to the compressor and condenser fan motor. Because the contacts make and break high current thousands of times per season, they eventually pit, burn, or weld. A failing contactor shows up as a buzzing or chattering sound, an outdoor unit that won't start, a fan or compressor that runs continuously even with the thermostat off (welded contacts), or visible arcing and pitting on the contact faces.

Specifications

Spec Value
Part Number 1178074
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fitment OEM replacement

Compatibility

Built for the ICP/Tempstar/Heil RHH060L0BA0AAAA and other condensing units and heat pumps that use a 2-pole, 30A, 24V-coil contactor. Verify pole count, amp rating, and coil voltage match your old part before installing.

Installation Guide

  1. Safety First – Disconnect power at the outdoor disconnect and breaker, then verify zero voltage across all contactor terminals with a multimeter.
  2. Access – Remove the service panel to reach the contactor.
  3. Document – Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove – Transfer wires one at a time or label them, then unscrew the old contactor from its bracket.
  5. Install – Mount the new contactor, reconnect each wire to the matching terminal per your photo, and tighten lugs to a secure fit.
  6. Test – Restore power, place a thermostat call, and confirm the contacts pull in cleanly with no chatter and the unit starts.

Signs You Need a Replacement

  • Buzzing, humming, or chattering at the outdoor unit
  • Pitted, burned, or welded contacts
  • Compressor/fan runs nonstop or won't start at all
  • 24V coil reads open or out of spec on a meter

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHH060L0BA0AAAA – OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHH060L0BA0AAAA – OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHH060L0BA0AAAA – OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart