Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A Contactor 24V Coil for RGS303LDEA0AAAA — OEM 1171554 | Ships Today
ICP

ICP 2-Pole 30A Contactor 24V Coil for RGS303LDEA0AAAA — OEM 1171554 | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is a genuine OEM 2-pole, 30-amp definite-purpose contactor with a 24-volt coil (part number 1171554) for the ICP / Tempstar / Heil RGS303LDEA0AAAA system. The contactor is the electromechanical switch that closes the high-voltage circuit to the compressor and condenser fan when the 24V control signal energizes its coil. Pitted, welded, or chattering contacts are one of the most common no-cool and no-start failures — symptoms include a humming contactor that won't pull in, intermittent operation, or contacts that stick closed and won't shut the unit off.

Specifications

Spec Value
Part Number 1171554
Description Contactor 2P 30A 24V
Type Definite Purpose, 2-Pole
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fits Model RGS303LDEA0AAAA
Fitment Genuine OEM

Compatibility

Designed for the ICP-built RGS303LDEA0AAAA and shared across the Tempstar, Heil and Comfortmaker family. Verify your existing contactor is a 2-pole, 30A unit with a 24V coil and matches OEM 1171554 before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage at the line terminals with a multimeter.
  2. Access — Remove the electrical/control service panel.
  3. Document — Photograph every line, load, and 24V coil wire before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unbolt the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo, confirming line/load and coil terminals.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and condenser fan energize.

Signs You Need a Replacement

  • Contactor hums or buzzes but won't pull in
  • Pitted, burned, or welded (stuck) contacts
  • Unit runs intermittently or won't shut off
  • Visible arcing or melted contactor housing

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303LDEA0AAAA — OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303LDEA0AAAA — OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303LDEA0AAAA — OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online