This genuine OEM 2-pole, 30-amp contactor with a 24-volt coil (part number 1178074) is the switching relay for the ICP/Tempstar/Heil RGS150LDCA0AAAA. When the thermostat calls for cooling, the 24V control signal energizes the coil, pulling the contacts closed to deliver line voltage to the compressor and condenser fan motor. Contactors are a high-failure wear item: their contacts pit, arc, and weld over thousands of cycles. A failed contactor is one of the most common causes of a no-cool call — either the unit won't start, or it won't shut off because the contacts have welded closed.

Specifications

Spec Value
Part Number 1178074
Type Definite-purpose contactor
Poles 2
Contact Rating 30 Amps
Coil Voltage 24 VAC
Brand ICP / Tempstar / Heil
Fit OEM

Compatibility

Direct OEM replacement for the ICP RGS150LDCA0AAAA and other units calling out part 1178074. Verify pole count, amp rating, and 24V coil against your old contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and verify zero voltage with a multimeter on both line terminals.
  2. Access — Remove the electrical service panel to expose the contactor.
  3. Document — Photograph every wire and terminal before disconnecting anything.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from its bracket.
  5. Install — Mount the new 2-pole contactor, transfer each wire to the matching terminal per your photo, and confirm the coil leads land on the 24V terminals.
  6. Test — Restore power, call for cooling, and verify the contacts pull in cleanly and the compressor/fan energize.

Signs You Need a Replacement

  • Unit won't start on a cooling call (no click, no pull-in)
  • Compressor or fan runs continuously and won't shut off (welded contacts)
  • Pitted, blackened, or burned contacts on inspection
  • Loud buzzing or chattering from the contactor

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150LDCA0AAAA — OEM 1178074 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150LDCA0AAAA — OEM 1178074 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150LDCA0AAAA — OEM 1178074 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.