Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A / 40A Definite Purpose Contactor for RGS150HDAA0AAAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A / 40A Definite Purpose Contactor for RGS150HDAA0AAAA — 24V Coil | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

Genuine OEM 2-pole definite purpose contactor for the ICP / Tempstar / Heil RGS150HDAA0AAAA, available as a 30-amp (part 1178074) or 40-amp (part 1178211) unit, both with a 24-volt control coil. The contactor is the electrically operated switch that energizes the compressor and condenser fan motor when the thermostat calls for cooling. Pitted, burned, or chattering contacts cause hard starts, intermittent cooling, and welded contacts that leave the compressor running continuously. Replacing a worn contactor restores clean switching and protects the compressor from voltage-related damage.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30A or 40A
Coil Voltage 24V
Brand ICP (Tempstar / Heil)
Fit Genuine OEM

Compatibility

Fits the ICP / Tempstar / Heil RGS150HDAA0AAAA and related RGS-series equipment. Match the original contactor's amp rating (30A or 40A) and confirm the 24V coil before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the electrical access panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Label and remove the wires, then unscrew the old contactor from the mounting plate.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo, confirming the 24V coil leads.
  6. Test — Restore power, call for cooling, and verify the contacts pull in cleanly with no chatter.

Signs You Need a Replacement

  • Burned, pitted, or melted contact surfaces
  • Buzzing or chattering when energized
  • Compressor will not start or cycles intermittently
  • Contacts welded closed (system runs without a thermostat call)

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150HDAA0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150HDAA0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150HDAA0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online