Overview

This OEM 2-pole definite purpose contactor fits the ICP Tempstar/Heil RHS150H0EA0AAAA heat pump and is offered in both 30 amp (part 1178074) and 40 amp (part 1178211) ratings, each with a 24-volt control coil. The contactor is the high-current switch that energizes the compressor and condenser fan motor whenever the thermostat calls. Its contacts carry full line voltage and take a beating every cycle, so they pit, weld, or burn over time. A failing contactor causes hard starts, chatter, a humming buzz, or a unit that won't run at all. This genuine ICP replacement restores clean, reliable switching.

Specifications

Spec Value
30A Part Number 1178074 (Contactor 2P 30A 24V)
40A Part Number 1178211 (Contactor 2P 40A 24V)
Poles 2-Pole
Contact Rating 30A / 40A
Coil Voltage 24V
Brand ICP (Tempstar / Heil)

Compatibility

Built for the ICP Tempstar/Heil RHS150H0EA0AAAA and other ICP, Tempstar, Heil, and Comfortmaker condensing units using a 2-pole, 24V-coil definite purpose contactor. Verify whether your unit calls for the 30A or 40A rating before ordering.

Installation Guide

  1. Safety First – Shut off the breaker and pull the outdoor disconnect; verify zero voltage with a multimeter.
  2. Access – Remove the condenser service panel to expose the contactor.
  3. Document – Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove – Transfer wires one at a time, or label them, then unscrew the old contactor from its mount.
  5. Install – Mount the new contactor, reconnect each wire to the matching terminal per your photo, and torque snug.
  6. Test – Restore power, call for cooling, and confirm the contactor pulls in cleanly with no chatter and the compressor and fan run.

Signs You Need a Replacement

  • Loud humming or buzzing at the outdoor unit.
  • Pitted, burned, or welded-shut contacts.
  • Compressor and fan won't start on a cooling call.
  • Unit short-cycles or chatters when energizing.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS150H0EA0AAAA – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS150H0EA0AAAA – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS150H0EA0AAAA – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart