Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A/40A Contactor for RGS150SRAA0AGAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A/40A Contactor for RGS150SRAA0AGAA — 24V Coil | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM definite purpose contactor is the electrically-controlled switch that energizes the compressor and condenser fan in your ICP / Tempstar / Heil RGS150SRAA0AGAA system. When the thermostat calls for cooling, the 24-volt control coil pulls the contacts closed, sending line voltage to the outdoor unit. It is offered in two interchangeable ratings: OEM part 1178074 (2-pole, 30 amp) and OEM part 1178211 (2-pole, 40 amp), both with a 24V coil. A failing contactor is one of the most common causes of an outdoor unit that hums but won't start, or that won't shut off. Pitted, burned, or welded contacts and a chattering coil are classic failure signs.

Specifications

Spec Value
Part Number 1178074 (30A) / 1178211 (40A)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30 Amp / 40 Amp
Coil Voltage 24 VAC
Fitment OEM

Compatibility

Engineered for the ICP / Tempstar / Heil RGS150SRAA0AGAA and closely related gas furnace / condenser assemblies that use a 2-pole, 24V-coil definite purpose contactor. Choose the amp rating that matches the contactor currently in your unit.

Installation Guide

  1. Safety First — Disconnect power at the outdoor disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser service panel.
  3. Document — Photograph all line and 24V coil wires before disconnecting.
  4. Remove — Note each wire's terminal, disconnect them, and unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect every wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor and fan start.

Signs You Need a Replacement

  • Outdoor unit hums or buzzes but the compressor won't start.
  • Burned, pitted, or welded contacts visible on the old part.
  • Coil chatters or won't pull the contacts closed.
  • System won't shut off when the thermostat is satisfied.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150SRAA0AGAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150SRAA0AGAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150SRAA0AGAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online