This genuine OEM 2-pole definite-purpose contactor for the ICP / Tempstar / Heil RGS150HRCB0AAAA rooftop package unit switches line power to the compressor and condenser fan motor on a call for cooling. Available in 30-amp (OEM 1178074) and 40-amp (OEM 1178211) ratings, both with a 24-volt control coil. When the thermostat energizes the coil, the contacts pull in and route high-voltage power to the load. Pitted, welded, or chattering contacts are a leading cause of no-cool calls, hard starts, and burnt control wiring. Installing a fresh OEM contactor restores clean, reliable switching and protects the compressor.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite-Purpose Contactor
Poles 2-Pole
Contact Rating 30A or 40A
Coil Voltage 24V
Brand ICP / Tempstar / Heil
Fitment OEM

Compatibility

Fits the ICP RGS150HRCB0AAAA package unit and related ICP, Tempstar, Heil, and Comfortmaker units. Match the amp rating (30A or 40A) to your original contactor and confirm a 24V coil.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter at the contactor line terminals.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photo all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unfasten the old contactor.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in and the compressor and fan start.

Signs You Need a Replacement

  • Pitted, burnt, or welded contacts
  • Buzzing or chattering when energized
  • Compressor and fan won't start on a cooling call
  • Coil fails to pull the contacts in at 24V

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150HRCB0AAAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150HRCB0AAAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150HRCB0AAAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.