Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A & 40A Contactor for RGS150HDAB0AGAA – 24V Coil | Ships Today
ICP

ICP 2-Pole 30A & 40A Contactor for RGS150HDAB0AGAA – 24V Coil | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole definite-purpose contactor (available in 30-amp part 1178074 and 40-amp part 1178211, both with a 24V coil) is the high-voltage relay for the ICP/Tempstar/Heil RGS150HDAB0AGAA. When the thermostat calls for cooling, the 24V coil pulls the contacts closed to energize the compressor and condenser fan motor. Pitted, welded, or chattering contacts are one of the most common no-cool failures — a failed contactor can leave the compressor unable to start or stuck running.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite purpose contactor
Poles 2-pole
Coil Voltage 24V
Contact Rating 30A / 40A
Brand ICP / Tempstar / Heil
Fits Model RGS150HDAB0AGAA

Compatibility

Fits the RGS150HDAB0AGAA and related ICP-family condensing units. Confirm whether your unit uses the 30A or 40A version from the wiring label before ordering.

Installation Guide

  1. Safety First — Disconnect power and verify zero voltage with a multimeter at the contactor terminals.
  2. Access — Remove the unit's electrical service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Label and disconnect the wires, then unscrew the old contactor from the bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor/fan energize.

Signs You Need a Replacement

  • Buzzing or chattering at the contactor
  • Burnt, pitted, or welded-together contacts
  • Compressor won't start or won't shut off
  • Visible arcing or melted housing

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day returns. Covered by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150HDAB0AGAA – 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150HDAB0AGAA – 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150HDAB0AGAA – 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online