OEM Guaranteed
Same-Day Ship
30-Day Returns
Secure Checkout
This OEM 2-pole definite purpose contactor for the ICP/Heil/Tempstar RGS121HFCB0AAA system is available as a 30-amp version (part #1178074) and a 40-amp version (part #1178211), both with a 24-volt control coil. The contactor is an electrically operated switch that closes when the 24V thermostat circuit calls, sending line power to the compressor and condenser fan motor. Contactor contacts pit, weld, or burn over thousands of cycles — a failed contactor is a leading cause of a unit that hums but won't start or won't shut off. A genuine OEM contactor restores clean, reliable switching.
| Spec | Value |
|---|---|
| 30A Part Number | 1178074 (Contactor 2P 30A 24V) |
| 40A Part Number | 1178211 (Contactor 2P 40A 24V) |
| Type | Definite Purpose Contactor |
| Poles | 2-Pole |
| Contact Rating | 30A / 40A |
| Coil Voltage | 24V |
| Brand | ICP / Heil / Tempstar |
| Fits Model | RGS121HFCB0AAA |
| Application | Compressor / Condenser Fan Switching |
Direct OEM replacement for the ICP RGS121HFCB0AAA and equivalent RGS-series units built under the Heil, Tempstar and Comfortmaker brands. Match the amp rating (30A or 40A) and the 24V coil to your existing contactor before ordering.
Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.