ICP 2-Pole 30A/40A Contactor for RGS121HEBA0AAAA — 24V Coil OEM | Ships Today
ICP

ICP 2-Pole 30A/40A Contactor for RGS121HEBA0AAAA — 24V Coil OEM | Ships Today

SKU: 1178074-GEN Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole contactor is the switching relay that powers the compressor and condenser fan circuit on the ICP/Heil/Tempstar RGS121HEBA0AAAA system. A 24V control signal from the thermostat energizes the coil, pulling the contacts closed to deliver line voltage to the outdoor unit. Over time the contacts pit, burn, or weld, and the coil can fail — causing a unit that won't start, chatters, or won't shut off. This listing covers OEM 1178074 (2-pole, 30A, 24V) and 1178211 (2-pole, 40A, 24V) so you can match your system's amperage rating exactly.

Specifications

Spec Value
OEM Part Number 1178074 (30A), 1178211 (40A)
Type Definite purpose contactor, 2-pole
Brand ICP / Heil / Tempstar / Comfortmaker
Rating 30A or 40A
Coil Voltage 24V
Poles 2
Fit OEM direct replacement
Model RGS121HEBA0AAAA

Compatibility

Designed for the ICP family RGS121HEBA0AAAA and shared Heil, Tempstar, and Comfortmaker equipment. Match the amperage (30A 1178074 or 40A 1178211) and confirm the 24V coil before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker; verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control service panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time or label them, then unscrew and remove the old contactor.
  5. Install — Mount the new contactor (1178074 or 1178211) and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contacts pull in and the compressor/fan energize.

Signs You Need a Replacement

  • Burned, pitted, or welded contacts.
  • Buzzing or chattering when energized.
  • Unit won't start or won't shut off.
  • Coil fails to pull contacts in with 24V applied.

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS121HEBA0AAAA — 24V Coil OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS121HEBA0AAAA — 24V Coil OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS121HEBA0AAAA — 24V Coil OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online