This genuine OEM 2-pole definite-purpose contactor for the ICP Tempstar Heil RGS180HEAA0AAAA system is available in 30-amp (part 1178074) and 40-amp (part 1178211) ratings, both with a 24-volt control coil. The contactor is the high-voltage switch that energizes the compressor and condenser fan when the 24V thermostat circuit calls for cooling. Over time the silver contacts pit, burn, and weld from repeated arcing, causing hard starts, chattering, or a system that won't energize at all. Replacing a worn 2-pole contactor restores clean, reliable switching of line voltage to the outdoor unit. Choose the amp rating that matches your original contactor.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Brand ICP (Tempstar / Heil)
Poles 2-Pole
Contact Rating 30A / 40A
Coil Voltage 24V
Fits Model RGS180HEAA0AAAA
Fitment OEM Direct Replacement

Compatibility

Fits the ICP Tempstar Heil RGS180HEAA0AAAA and related RGS180 series condensing units across the ICP brand family (Tempstar, Heil, Comfortmaker). Match the 30A or 40A rating and confirm a 24V coil on your existing contactor.

Installation Guide

  1. Safety First — Disconnect power at the unit and verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control panel.
  3. Document — Photograph all line, load, and 24V coil wires before disconnecting.
  4. Remove — Transfer wires one at a time, or unfasten the old contactor from its mounting plate.
  5. Install — Mount the new contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor energizes.

Signs You Need a Replacement

  • Outdoor unit hums but won't start (welded or stuck contacts)
  • Buzzing or chattering at the contactor
  • Pitted, blackened, or burned contact surfaces
  • Intermittent cooling or hard starting

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS180HEAA0AAAA — OEM | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS180HEAA0AAAA — OEM | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS180HEAA0AAAA — OEM | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online