Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A & 40A 24V Contactor for RGS150HFAB0AGAA — OEM Set | Ships Today
ICP

ICP 2-Pole 30A & 40A 24V Contactor for RGS150HFAB0AGAA — OEM Set | Ships Today

SKU: 1178074 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

These genuine ICP 2-pole definite-purpose contactors switch line power to the compressor and condenser fan motor on your RGS150HFAB0AGAA packaged unit. The set covers both the 30-amp version (part 1178074) and the 40-amp version (part 1178211), each with a 24-volt control coil. When the thermostat calls for cooling, the 24V coil energizes and pulls the contacts closed to deliver high-voltage power to the compressor and fan. Pitted, welded, or chattering contacts are one of the most common causes of a no-cool condition, hard starting, or a unit that won't shut off. Match the amp rating to your original contactor before installing.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite Purpose Contactor
Poles 2-Pole
Contact Rating 30A / 40A
Coil Voltage 24V
Brand ICP (Tempstar / Heil)
Fitment OEM

Compatibility

Fits the ICP/Tempstar/Heil RGS150HFAB0AGAA packaged unit and many RGS-series models. Select 30A or 40A to match the contactor currently installed and the unit's load rating.

Installation Guide

  1. Safety First — Disconnect power at the unit disconnect and verify zero voltage with a multimeter on the line terminals.
  2. Access — Remove the electrical control panel cover.
  3. Document — Photograph all line, load, and 24V coil wiring before disconnecting.
  4. Remove — Unfasten the old contactor and transfer wires one at a time to avoid mix-ups.
  5. Install — Mount the new contactor and land each wire on the matching terminal per your photo.
  6. Test — Restore power, call for cooling, and confirm the coil pulls in and the compressor/fan energize.

Signs You Need a Replacement

  • Buzzing, chattering, or humming from the contactor
  • Pitted, burned, or welded contacts
  • Compressor or fan won't start, or won't shut off
  • Intermittent no-cool calls

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS150HFAB0AGAA — OEM Set | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS150HFAB0AGAA — OEM Set | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS150HFAB0AGAA — OEM Set | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online