This OEM definite purpose contactor for the ICP (International Comfort Products) RGS101HFAA0AAAA system is a 2-pole unit with a 24-volt coil, available in both 30 amp (part 1178074) and 40 amp (part 1178211) ratings. The contactor is the electrically operated switch that energizes the compressor and condenser fan motor when the thermostat calls for cooling. The 24V coil pulls the contacts closed to pass line voltage to the load. Contactors are among the most common failure points in HVAC systems: contacts pit and burn from arcing, and coils weaken or stick, causing no-cool calls, chattering, or a system that won't shut off. A fresh OEM contactor restores reliable switching.

Specifications

Spec Value
Part Numbers 1178074 (30A), 1178211 (40A)
Type Definite purpose contactor, 2-pole
Brand ICP / Heil / Tempstar
Contact Rating 30A and 40A options
Coil Voltage 24V
Poles 2
Fit OEM exact replacement

Compatibility

Fits the ICP RGS101HFAA0AAAA and related Heil, Tempstar, and Comfortmaker equipment using a 2-pole 24V definite purpose contactor. Match the amp rating (30A or 40A) and coil voltage to your existing contactor before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical/control service panel.
  3. Document — Photograph every wire on the contactor terminals before disconnecting.
  4. Remove — Transfer one wire at a time, or label each lead, then unfasten the old contactor from its mount.
  5. Install — Mount the new contactor and reconnect the line, load, and 24V coil wires exactly per your photo.
  6. Test — Restore power, call for cooling, and confirm the contactor pulls in cleanly and the compressor and fan start.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Chattering or buzzing when the system calls for cooling
  • Compressor won't start or won't shut off
  • Coil hums but contacts fail to close

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS101HFAA0AAAA — OEM Definite Purpose | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS101HFAA0AAAA — OEM Definite Purpose | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS101HFAA0AAAA — OEM Definite Purpose | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online