Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A & 3-Pole 40A Contactor Set for RGS181HEBB7CGAA — 24V Coil | Ships Today
ICP

ICP 2-Pole 30A & 3-Pole 40A Contactor Set for RGS181HEBB7CGAA — 24V Coil | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM contactor set fits the ICP / Tempstar / Heil RGS181HEBB7CGAA and includes a 2-pole 30-amp contactor (part #1171554) and a 3-pole 40-amp contactor (part #1172449), both with a 24-volt control coil. A contactor is an electrically operated switch that uses the low-voltage 24V signal from the control board or thermostat to close high-voltage contacts and energize the load. Pitted, burned, or chattering contacts are a leading cause of no-start conditions, buzzing, and welded-closed failures that keep equipment running continuously. Fresh OEM contactors restore reliable, clean switching.

Specifications

Spec Value
OEM Part Numbers 1171554 (2P 30A), 1172449 (3P 40A)
Type 2-Pole & 3-Pole Contactor
Brand ICP (Tempstar / Heil / Comfortmaker)
Contact Rating 30A (2P) / 40A (3P)
Coil Voltage 24V
Fits Model RGS181HEBB7CGAA

Compatibility

Direct OEM replacements for the ICP RGS181HEBB7CGAA and shared-platform Tempstar, Heil, and Comfortmaker units calling for a 24V 30A 2-pole or 40A 3-pole contactor. Match pole count, amp rating, and coil voltage to your existing part before installing.

Installation Guide

  1. Safety First — Disconnect all power and verify zero voltage with a multimeter.
  2. Access — Remove the electrical service panel.
  3. Document — Photograph every wire and terminal before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil leads; unbolt the old contactor.
  5. Install — Mount the new contactor and reconnect each wire per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly with no chatter.

Signs You Need a Replacement

  • Buzzing, humming, or chattering at the contactor
  • Pitted, burned, or melted contacts
  • Equipment fails to start or won't shut off (welded contacts)
  • Visible arcing or corrosion on the terminals

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS181HEBB7CGAA — 24V Coil | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS181HEBB7CGAA — 24V Coil | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS181HEBB7CGAA — 24V Coil | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online