Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RHS183S0CA0AAAA — Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RHS183S0CA0AAAA — Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This OEM 2-pole, 30-amp definite purpose contactor with a 24V coil is the electrical switch that energizes the compressor and condenser fan in your ICP RHS183S0CA0AAAA heat pump. When the thermostat calls, the 24V coil pulls the contacts closed to deliver line voltage to the outdoor unit. Pitted, welded, or chattering contacts are a frequent cause of a unit that won't start, won't shut off, or buzzes loudly at the disconnect. A heavier 3-pole 40A option (1172449) is also referenced for higher-capacity configurations.

Specifications

Spec Value
Part Numbers 1171554 (2P 30A 24V), 1172449 (3P 40A 24V)
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Amp Rating 30A
Coil Voltage 24V

Compatibility

Direct OEM replacement for the ICP/Tempstar/Heil RHS183S0CA0AAAA heat pump and related RHS-series condensing units. Match poles, amp rating, and 24V coil voltage to your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the condenser electrical-compartment panel.
  3. Document — Photograph the line, load, and coil (24V) connections before disconnecting.
  4. Remove — Disconnect all leads, unscrew the contactor from the bracket, and lift it out.
  5. Install — Mount the new contactor and reconnect each lead to its matching terminal per your photo.
  6. Test — Restore power and confirm the contacts pull in cleanly on a thermostat call.

Signs You Need a Replacement

  • Loud buzzing or chattering from the contactor
  • Pitted, burned, or welded contacts
  • Compressor won't start or won't shut off
  • Coil fails to pull the contacts closed on a call

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RHS183S0CA0AAAA — Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RHS183S0CA0AAAA — Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RHS183S0CA0AAAA — Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online