The ICP OEM Contactor (part number 1171554) is a 2-pole, 30-amp switching relay with a 24-volt control coil used in the RGS303LSEA0AAAA system. The 24V coil energizes from the control circuit to close the line-voltage contacts that power the load. Over time contactors fail from pitted or welded contacts, a burned-out coil, or chattering, which causes the unit to fail to start, run continuously, or buzz loudly. This OEM contactor restores clean, reliable switching with the correct 30A / 24V ratings.

Specifications

Spec Value
Part Number 1171554
Description Contactor 2P 30A 24V
Type 2-Pole Contactor
Poles 2
Contact Rating 30 Amps
Coil Voltage 24V
Brand ICP (Tempstar / Heil / Comfortmaker)
Fits Model RGS303LSEA0AAAA
Fitment OEM Direct Replacement

Compatibility

Specified as the factory 2-pole, 30A, 24V contactor for the ICP Tempstar Heil RGS303LSEA0AAAA system. Terminal layout and mounting match the original for a direct swap. Verify your model number and the existing contactor's coil voltage and amp rating before ordering.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker and verify zero voltage with a multimeter.
  2. Access — Remove the electrical-compartment service panel.
  3. Document — Photograph all line, load, and coil wiring before disconnecting.
  4. Remove — Label and disconnect the wires, then unscrew and remove the old contactor.
  5. Install — Mount the new 30A 24V contactor and reconnect each wire to the matching terminal per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly with no chatter when energized.

Signs You Need a Replacement

  • Pitted, burned, or welded contacts
  • Loud humming or chattering when energized
  • Unit fails to start or runs continuously
  • Coil does not pull the contacts in on a call

Shipping & Returns

Ships same day on orders placed before 3 PM CST. 30-day hassle-free returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303LSEA0AAAA — OEM Fit | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303LSEA0AAAA — OEM Fit | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303LSEA0AAAA — OEM Fit | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online