Same-day shipping before 3PM CST · 35,000+ OEM Parts · Texas CMBL & SAM.gov Registered · Government POs Accepted

Menu

Home Shop All Account Cart
ICP 2-Pole 30A 24V Contactor for RGS303LFAA0AAAA — OEM 1171554 | Ships Today
ICP

ICP 2-Pole 30A 24V Contactor for RGS303LFAA0AAAA — OEM 1171554 | Ships Today

SKU: 1171554 Brand: ICP

OEM Guaranteed

Same-Day Ship

30-Day Returns

Secure Checkout

Texas CMBL #19328542014
SAM.gov Registered
Govt POs Accepted

Overview

This is the OEM 2-pole, 30-amp, 24-volt definite-purpose contactor (ICP part number 1171554) for the ICP / Tempstar / Heil RGS303LFAA0AAAA system. The contactor is the electrically-controlled switch that closes when the 24V coil is energized by the thermostat, sending line voltage to the compressor and condenser fan motor. Pitted, welded, or chattering contacts are a leading cause of a unit that won't start, intermittent cooling, or a buzzing condenser. This direct OEM replacement restores reliable switching with factory-rated contacts.

Specifications

Spec Value
Part Number 1171554
Type Definite Purpose Contactor
Brand ICP / Tempstar / Heil
Poles 2-Pole
Contact Rating 30 Amp
Coil Voltage 24V
Fit OEM Direct Replacement

Compatibility

Designed for the ICP / Tempstar / Heil RGS303LFAA0AAAA and other Heil-built ICP-family systems using a 2-pole 30A 24V coil contactor. Verify pole count, amperage, and coil voltage against your existing contactor before installing.

Installation Guide

  1. Safety First — Disconnect power at the disconnect and breaker, then verify zero voltage with a multimeter.
  2. Access — Remove the electrical access panel on the condensing unit.
  3. Document — Photograph every wire and terminal position before disconnecting.
  4. Remove — Label and disconnect the line, load, and 24V coil leads, then unscrew the old contactor from its bracket.
  5. Install — Mount the new contactor and reconnect each wire exactly per your photo.
  6. Test — Restore power and confirm the contactor pulls in cleanly on a call for cooling with no chatter.

Signs You Need a Replacement

  • Buzzing or chattering noise from the contactor
  • Burned, pitted, or welded contacts
  • Compressor and fan won't start on a cooling call
  • Intermittent cooling or unit that runs after the thermostat is satisfied

Shipping & Returns

Ships same day before 3 PM CST. 30-day returns. Backed by the National HVAC Parts fitment guarantee.

Shipping Information

  • Orders placed before 3PM CST ship same business day
  • Standard delivery: 2-5 business days
  • Express shipping available at checkout
  • Free shipping on orders over $75
  • Tracking number emailed upon shipment

Return Policy

  • 30-day returns on unused parts in original packaging
  • Electrical parts (capacitors, contactors, control boards) are final sale once installed
  • Email info@nationalhvacparts.com to initiate a return
  • Refunds processed within 5-7 business days

Frequently Asked Questions

Does this Contactor fit my ICP RGS303LFAA0AAAA — OEM 1171554 | Ships Today?
Yes. This is the factory-specified OEM contactor for the ICP RGS303LFAA0AAAA — OEM 1171554 | Ships Today. It is a direct drop-in replacement that fits without modification. Always verify the model number on your equipment nameplate before ordering.
How do I replace the contactor on my ICP RGS303LFAA0AAAA — OEM 1171554 | Ships Today?
Difficulty: Medium (30–45 min)
Step 1: Turn off breaker. Step 2: Open condensing unit panel. Step 3: Photograph ALL wiring on the contactor. Step 4: Label each wire with tape. Step 5: Disconnect wires and remove old contactor. Step 6: Mount new contactor, reconnect wires matching your photo. Step 7: Restore power and test.
My AC clicks but the compressor won’t turn on. What’s wrong?
Clicking from the outdoor unit without the compressor starting = worn contactor. The contactor sends power to the compressor. When its contacts are pitted, it clicks but can’t make solid contact. Look for: visible pitting/burn marks on the contactor face, intermittent operation, or buzzing.
Is this contactor compatible with Bryant or Payne too?
Many ICP parts are cross-compatible with Bryant and Payne since all three brands are manufactured by Carrier Global Corporation. The same physical part is often used across brand labels with different model numbers. To verify: check your Bryant or Payne equipment service manual for cross-compatible part numbers, or email info@nationalhvacparts.com with your model number.
Should I use OEM or aftermarket for my ICP contactor?
OEM recommended for reliability and warranty compatibility. OEM parts match exact factory specifications for proper fit, performance, and safety. While aftermarket alternatives cost less upfront, the risk of improper fit and reduced lifespan usually makes OEM the better value long-term.
How fast does National HVAC Parts ship?
Orders placed before 3:00 PM CST ship the same business day. Standard delivery is 2–5 business days anywhere in the continental United States. Express shipping available at checkout. We ship from Houston, TX to all 50 states. 30-day return policy on all parts.
Home Shop Search Account Cart
Fitment Guaranteed
MR
Mike Rivera
HVAC Parts Specialist — Online